Every HMO licence application City of York Council accepts has to arrive with a set of supporting documents, and one of them trips landlords up more often than the rest. Alongside the gas safety certificate, the electrical safety certificate, the EPC, the written fire risk assessment and a floor plan of the property, the council asks for a portable appliance test report covering the appliances supplied with the property. Its online licensing system states that the PAT report must be dated within the last two years. An application submitted without one is not a valid application, and the clock on your existing licence keeps running while you sort it out.

Two years, not five

The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 require an EICR on the fixed installation at intervals of no more than five years, with local authorities able to impose civil penalties of up to £30,000 for a breach. That five-year rhythm is the one most landlords have in their heads. York's licensing paperwork runs on a shorter cycle for appliances, so a landlord who books everything around the EICR anniversary can reach renewal with a satisfactory EICR and a PAT report that is three or four years old. The council will ask for a current one before it processes the application.

Three-person shares are caught too

Mandatory licensing applies across England to HMOs occupied by five or more people forming two or more households. Since 1 April 2023, York has also run an additional licensing scheme covering HMOs with three or four tenants in more than one household across eight designated electoral wards, which take in much of the student and young-professional rental stock near the universities and the city centre. Those smaller properties need the same supporting documents as a seven-bedroom house, including the appliance test report. If you own a three-bed share that has quietly let itself for a decade, it is worth checking the ward against the council's designation rather than assuming the scheme is only for large student houses.

Which appliances the report should cover

The duty runs to equipment you supply, so that usually means the fridge freezer, washing machine, tumble dryer, microwave, kettle, toaster, vacuum cleaner, any plug-in cooker or hob, table and floor lamps, and any extension leads or multi-way adaptors left in the property between tenancies. Those last two are worth pulling out of the cupboard and testing rather than ignoring, because in a shared house they tend to end up powering a lot more than they were bought for. Tenants' own equipment sits outside your legal responsibility under the Management of Houses in Multiple Occupation (England) Regulations 2006, which cover fixtures, fittings and appliances you provide. Some landlords still ask us to test student-owned items while we are on site, and in a house with six bedrooms of chargers, hair tools and gaming kit that can be a sensible addition to the fire risk assessment.

Landlord or agent: who books it

The 2006 management regulations place their duties on the person managing the HMO, which in a fully managed let is often the letting agent rather than the owner. The same regulations require the manager to supply electrical and gas safety documents to the local housing authority within seven days of a written request. That short deadline is the reason it pays to agree in writing who holds the compliance file, who books the testing and who uploads the report at renewal. We work with agents and portfolio landlords who hand us a list of addresses and access arrangements once a year, which keeps the certificate dates aligned across a block of properties instead of drifting apart one tenancy at a time.

Fitting it into the student year

York student tenancies commonly end in late June or early July, with the next group moving in on 1 July or in early September. That void window is the easiest time to get into every room, check the kitchen appliances properly and deal with anything that fails before new tenants arrive. It is also the busiest period for testing in the city, so booking early tends to get you the slot you want. A single house usually fits into an hour, from £50, and grouping several properties in the same area into a half day from £125 or a full day from £250 brings the cost per property down.

What a usable report looks like

Stickers on plugs are not the evidence the council wants. The report should list every item tested with its location, the test date, the result, and details of anything that failed along with what was done about it. Keep it in the same folder as the EICR, the gas certificate and the fire risk assessment so a renewal application or a council request can be answered the same day. If you want to talk through a property or a portfolio, our York team covers the city, the surrounding villages and the wider North Yorkshire area.

Frequently Asked Questions

Do I need a PAT certificate to apply for an HMO licence in York?
Yes. City of York Council's HMO licensing system lists a portable appliance test report for appliances supplied with the property among the required supporting documents, and states it must be dated within the last two years. It sits alongside the gas safety certificate, the electrical safety certificate, the EPC, a written fire risk assessment and a floor plan. An application submitted without all of these is not treated as valid.

Is PAT testing a legal requirement for HMOs in England?
No single law uses the words "PAT testing", but several duties add up to it in practice. The Management of Houses in Multiple Occupation (England) Regulations 2006 require the manager to keep appliances they supply in good and safe repair, the Electrical Equipment (Safety) Regulations 2016 cover the safety of equipment provided, and many councils, including City of York, make a current PAT report a condition of licensing. For a licensed HMO in York, testing is effectively required.

Does an EICR cover the appliances in my student house?
No. An EICR assesses the fixed electrical installation, meaning the consumer unit, wiring, sockets, switches and lighting points, and it is required at intervals of no more than five years under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020. Anything that plugs into a socket, such as the fridge freezer, washing machine, microwave or a lamp, falls outside it. Those items are covered by appliance testing instead.

Do tenants' own appliances in an HMO need PAT testing?
Your legal duty covers equipment you supply, not items tenants bring with them, so tenant-owned kettles, hair tools and chargers are not your responsibility to test. Some landlords and agents still ask for them to be included while an engineer is on site, particularly in larger shared houses where a lot of personal equipment shares the same sockets. If you do test tenant items, record them separately from the landlord-supplied list so the licensing report stays clear.

When is the best time to book PAT testing for a York student let?
The void period between tenancies is usually the easiest window, which in York often falls between late June and early September when one group has moved out and the next has not yet arrived. Access to every bedroom and the kitchen is straightforward, and anything that fails can be replaced before the new tenancy starts. Book ahead if you can, because that window is the busiest part of the year for testing in the city.