If you run a student HMO in Sheffield, the question we hear most is simple: how often does the PAT testing need doing? The honest answer is that no rule gives you a number. What exists is good practice, and for a student house it is easy to follow.
What the guidance says
The IET Code of Practice for in-service inspection and testing does not set one fixed interval for everything. It is risk-based. The more an appliance is used, moved or abused, the more often it should be checked. A kettle in a house with six students gets a harder life than a lamp in a spare room.
What most Sheffield landlords do
For landlord-supplied appliances in a student let, the usual pattern is one of two things: test every year, or test at each change of tenancy. Because most student tenancies in Sheffield end in the summer, those two often land in the same month. We see most of our student house bookings in June, July and August, with landlords wanting the work finished between tenants.
If a house has a long tenancy, or a tenant moves out mid-year, an annual test is still the safer rule of thumb.
What can shorten the interval
- A recent fail. If an appliance failed last time, check it again sooner.
- Appliances behind fitted units or heavy furniture, where leads get crushed.
- Lots of extension leads and blocks, which are the commonest cause of problems.
- A history of tenants swapping appliances around.
What happens when something fails
Most failures in a student house are a damaged plug, a loose connection in a plug or a cracked extension socket. We fix those on the spot with a new plug or fuse. Anything we cannot fix safely is taken out of use and listed on the report with the reason, so you can replace it before the next tenants arrive.
PAT testing is not the whole picture
PAT testing covers the appliances you supply. The fixed wiring is separate. Private landlords in England need an EICR at least every five years, and that is a different inspection, done by an electrician. For an HMO, check the licence conditions with Sheffield City Council, because they can add their own requirements.
Booking it
A typical house is 25 to 40 items and takes about an hour. Smaller jobs are £50, medium-sized properties £125 and larger sites £250, and a portfolio or repeat annual booking is priced as a package. Each house gets its own certificate and register, emailed the same day.
See our Crookes and Broomhill page, our HMO and student let page, or our guide for Sheffield student landlords and letting agents.
Frequently Asked Questions
How often should I PAT test a Sheffield HMO?
There is no fixed legal interval. The usual practice for landlord-supplied appliances in a student let is every year or at each change of tenancy, whichever comes first. The IET Code of Practice is risk-based, so heavily used appliances can need checking more often.
Do I need to PAT test every time a new tenant moves in?
Not legally, but testing between tenancies is the cleanest time, because the house is empty. Many Sheffield landlords test every summer, when most student tenancies end.
What is the difference between PAT testing and an EICR?
PAT testing checks the portable appliances you supply. An EICR checks the fixed wiring and consumer unit and is done by an electrician. Private landlords in England need an EICR at least every five years.
Does Sheffield City Council require PAT testing for HMO licences?
Licence conditions vary by property and scheme, so check the specific conditions on your own licence with Sheffield City Council.